Doors | Advanced Options

Advanced Options

  • Update User Area When Passback Disabled * : When enabled the door will update the user's current area, even if the door is not programmed with card Antipassback. This can be used to keep track of the last area the user entered.
  • Lock Out REX When Inside Area Armed: When enabled the door will deny a request to exit when the inside area has been armed to prevent egress from an armed area.
  • Deny Entry if Inside Area is Armed: When enabled the door will deny entry if the inside area is armed.
  • Deny Exit if Outside Area is Armed: When enabled the door will prevent any exit if the outside area is armed.
  • Disable Door Alarms on Schedule Unlock: When enabled the door will not generate the door left open alarm events to any reader expander's programmed beeper and LED ports. This allows a door to be 'propped open' during normal opening times, however a pre-alarm warning will still be generated. This option DOES NOT prevent the door left open trouble input being sent to the monitoring station if reporting on the trouble input is programmed. To prevent the door open alarms from being sent, schedule the input type for the door open alarm events to operate without reporting during the day.
  • Prompt User For Access Reason Code: When enabled the user will be prompted on the reader expander's associated keypad to enter their reason for access. The user must enter the reason before access will be granted.
  • Enable Access Taken on Door Unlock Events: When enabled the door will generate a User Access Taken event if the door opens while the door is unlocked after entry has been granted. If the door remains closed, an Access Not Taken event is generated.

Extended Access Time Options

  • Door Extended Access Time: The duration (in seconds) the door remains opens for users tagged as requiring extended access.
  • Antipassback Entry User Reset Time * : The duration (in minutes) before resetting the antipassback on entry. Requires the Enable Timed Users Antipassback Reset option to be activated in the Controller settings.
  • Antipassback Exit User Reset Time * : The duration (in minutes) before resetting the Antipassback on exit. Requires the Enable Timed Users Antipassback Reset option to be activated in the Controller settings.
  • Reset Antipassback Status On Schedule * : When enabled resets the antipassback status of all users, using a defined schedule.
  • Enable Timed User Antipassback Reset * : When enabled antipassback is reset according to User Reset Time.