Keypads | Options 1

Display Options

  • Display Custom Message (lines 1 and 2): When enabled the keypad will display the text programmed in the Controller settings.
  • Display Primary Area Status: When enabled the keypad will display the status of the primary area that is assigned to the keypad.
  • Display Scrollable Area Group: When enabled the keypad will display the status of the area's that are assigned in the area group.
  • Display Trouble Message: When enabled the keypad will display the trouble input(s) when a failure has occurred.
  • Display Bypass Message: When enabled the keypad will display the message input(s) bypassed when an input has been bypassed in the system or primary area if the Display Primary Area Messages Only option is also enabled.
  • Display Alarm Message: When enabled the keypad will display the message alarm(s) in memory.
  • Display Primary Area Messages Only: When enabled in conjunction with the Display Alarm Message option, the keypad will only display the bypassed input status and alarm memory for the primary area of the keypad. Setting this option means that only the primary area's alarms are shown, in which case the alarm message is cleared only if the primary area's memory is acknowledged. If this option is not enabled any area that has an alarm stored in memory is shown and all the area's memory must be acknowledged before this message is cleared.
  • Display Defer Area Warning Messages * : When enabled the keypad will allow defer messages to be shown on the keypad for any area that is in the defer mode and the keypad is part of the defer warning keypad group.

Access Options

  • Function Key Unlocks Door When Logged In (REX): When enabled allows the user to unlock the controlled door by pressing the FUNCTION key when they are logged in.
  • Keypad Can Access Only Primary Area: When enabled the keypad will only allow the user to access the keypad's primary area.
  • Allow Area Group Selection Access: When enabled the keypad will allow the area group access screen to be accessed by the user.
  • Allow 24HR Area Access: When enabled the keypad will allow the 24HR status screen of an area to be accessed by the user. The user must have the 24HR menu option set.
  • Function Key Unlocks Door When Logged Out (REX): When enabled allows the user to unlock the controlled door by pressing the FUNCTION key when they are logged out.
  • Auto Logout After User Arming: When this option is enabled, the keypad will automatically log the user out when an area is successfully armed or disarmed. This can prevent third parties from accessing the keypad if the user forgets to log out.
  • Lock Keypad On Excess Attempts: When enabled the keypad will lock if a user makes 3 invalid attempts to log on.
  • Activate Access Level Output * : When enabled the keypad will activate the output assigned to the user's access level upon a valid user code being entered.